Ensuring Rugged Reliability for Texas Industrial Power Supplies
Inquiry by email Inquiry by whatsapp
An industrial automation company based in Texas reached out to us with a recurring problem: their power supply PCBs were overheating under peak loads in harsh oilfield environments.
The Analysis:
After reviewing their failed samples, we realized the standard 1oz copper weight was insufficient for their 20A current requirements. Heat was bottlenecking at the thermal vias, leading to delamination over time.
Our Approach:
We recommended upgrading to a 3oz heavy copper PCB. To ensure the integrity of the solder mask on such thick copper, we applied a double-print process. Furthermore, we utilized high-TG FR4 material (IT-180A) to ensure the board could withstand the ambient heat of the Texas summer.
The Feedback:
The customer reported a $15^\circ\text{C}$ drop in operating temperature. They appreciated that we didn't just "take the order" but actively proposed a material upgrade that saved their reputation in the field.